Valve Material
|
Noryl
|
|
Inlet/Outlet
|
1" with option of 1" or 3/4" NPT
|
|
Cycles*
|
5
|
|
|
Flow Rate (50 psi inlet)
|
Valve Alone
|
|
Continuous (15 psi drop)
|
l9gpm
|
|
Peak (25 psi drop)
|
24gpm
|
|
Cv**
|
5
|
|
Maximum Backwash (25 psi drop)
|
17gpm
|
|
|
Regeneration:
|
|
|
Downflow
|
Yes
|
|
Adjustable
|
Yes
|
|
Time Available
|
164 minutes
|
|
|
Meter Accuracy Range
|
.25-l5gpm +/-5%
|
|
Meter Capacity Range
|
Standard: 125 - 2,125 gals.
|
|
Extended: 625 - 10,625 gals.
|
|
|
Dimensions:
|
|
|
Distributor Pilot
|
1"
|
|
Drain Line
|
1/2"Q.C.
|
|
Brine Line
|
3/8
|
|
Mounting Base
|
2-1/2"- 8 Straight Q.C.
|
|
Height (from top of tank)
|
5-1/2"
|
|
|
Tank Application - can regenerate/backwash the following:
|
|
|
Water Softener
|
6"-16" diameter(limited by injector size)
|
|
Iron Filter
|
8" - 16" diameter (based on 10 gpm per sq. ft.)
|
|
Sediment Filter
|
8" - 16" diameter (based on 10 gpm per sq. ft.)
|
|
Carbon Filter
|
8" - 16" diameter (based on 10 gpm per sq. ft.)
|
|
Neutralizing Filter
|
8" - 16" diameter (based on 10 gpm per sq. ft.)
|
|
|
Electrical Rating
|
24v, 110v, 220v -50Hz, 60Hz
|
|
Pressure
|
Hydrostatic: 300 psi
|
|
Working: 20 - 125 psi
|
|
Temperature
|
340F- 1100F
|
|
|
*Cycles
|
Typical Time:
|
|
1. Backwash (Upflow)
|
10 minutes
|
|
2. Brine and Slow rinse (Downflow)
|
60 minutes
|
|
3. Rapid Rinse (Downflow)
|
10 minutes
|
|
4. Brine Tank Refill
|
10 minutes
|
|
5.Service (Downflow)
|
|
|
|
|
**CV - Flow rate of valve alone at 1 psi pressure
drop
|
|
|
Options:
|
|
|
Bypass valve
|
|
|
Backwash filter
|
|
|
Meter initiated regeneration
|
|
|
Manual operation
|
|
|
Service valve operator
|
|
|
No hard water bypass piston
|
|
|
Electronic timer
|
|
|
Environmental cover
|
|
|
90 degree adapter coupling
|
|