(Left) Prefilters and RO for laboratory water for a large paper mill. The boxes next to the pressure gauges are part of a remote monitoring system. Notice the unioned valving for easy service and and continued operation during filter changes. The RO is a Water Factory ACRO with its own percent rejection monitoring system, automatic shut down, flush, auto restart and pre-treatment lockout control. There are other commercial units that can do even more. See our Water Factory Section for more details.
|
(Right) You see the storage tank and post filters for the same system as above. The post filters consist of .35 micron and .5 micron absolute filters in housings with double o-ring filter seals. The large piece sticking out of the tank is part of a remote water level monitor. There is a remote sensor, not shown in these pictures, that detects flow and allows the operator to remotely determine the operating condition of the RO.